REKONDISI TRANSFORMATOR UNTUK MENGATASI MENURUNNYA KEMAMPUAN ISOLASI PADA TRANSFORMATOR DISTRIBUSI 20 kV

Penulis

  • Nasrul Harun Politeknik Negeri Padang

Kata Kunci:

Transformer, Insulator, Recondition of Transformer

Abstrak

Transformer insulator is an important part in electrical devices because it can muffle breakdown voltage and current interference. Refinement of transformer insulator can be done by replacing previous insulator such as recondition of electrical coils resistance and transformer oil.

Recondition of transformer should be donein insulator of electrical coil especially if this coil was burned before. This breakage can causeno voltage in one of transfomer phase. Reparation which should bedone is substitution of secondary electrical coil and oil transformer.

Referensi

Hotdes Lumbanraja. 2008. ”Pengaruh Beban Tidak Seimbang Terhadap Effisiensi Transformator Tiga Fasa Hubungan Open-Delta”. Tugas Sarjana. Medan: Teknik Elektro Fakultas Teknik Universitas Sumatra Utara

AS Pabla. 1981. Electric Power Distribusi Systemss. Systems Distribusi Daya Listrik. Terjemahan oleh Ir. Abdul hadi: Erlangga

SPLN 8-1 : 1991. Tarafo Tenaga.No001.K/0594 DIR/1991, Tanggal 18 Januari 1991

SPLN 8-2: 1991. Kenaikan Suhu.No 002K/0594.DIF :1991, Tanggal 18 Januari1991

SPLN_8-3-1_1991. Tingkati Isolasi Dan Uji Dielektrik Jarak Bebas Luar di Udara. No.004 K/0594 DIR/1991, 25 April 1991

SPLN_8-4_199. Sadapan dan Hubungan. No.109.K/0594 DIR/1991, Tanggal 28 September 1991

SPLN 8-5_1991. Kemampuan Menahan Hubung Singkat. No.107.K/0594DIR/1991, Tanggal 28 September1991

SPLN_8a_1978_Trafo Tenaga_(Umum). No.033.K/0594 DIR/1978.Tanggal 14 Aguatus 1978

SPLN_8b_1978_Trafo Tenaga (Kenaikan Suhu). No.033.K/0594DIR/1978. Tanggal 14 Aguatus 1978

SPLN_7_1978 Pemilihan Tingkat Isolasi. No.032.K/0594 DIR/1978. Tanggal 14 Aguatus 1978

SPLN_7a_1978. Koordinasi Isolasi. No.032.K/0594 DIR/1978. Tanggal 14 Aguatus 19781.

SPLN_8a_1978_Trafo Tenaga_(Umum). No.033.K/0594 DIR/1978. Tanggal 14 Aguatus 1978

SPLN_8b_1978_Trafo Tenaga (Kenaikan Suhu). No.033.K/0594DIR/1978. Tanggal 14 Aguatus 1978

SPLN_7_1978 Pemilihan Tingkat Isolasi. No.032.K/0594 DIR/1978. Tanggal 14 Aguatus 1978

SPLN_7a_1978. Koordinasi Isolasi. No.032.K/0594 DIR/1978. Tanggal 14 Aguatus 1978

Unduhan

Diterbitkan

2016-01-31

Cara Mengutip

REKONDISI TRANSFORMATOR UNTUK MENGATASI MENURUNNYA KEMAMPUAN ISOLASI PADA TRANSFORMATOR DISTRIBUSI 20 kV. (2016). Jurnal Teknik Elektro, 5(1), 29-33. https://jte.itp.ac.id/index.php/jte/article/view/654